Moxa Iologik R1240 R1240-T Universal I/O Module
The Moxa ioLogik R1240 / R1240-T is a compact and intelligent Universal I/O Module designed for industrial monitoring, automation, and remote control applications. With Ethernet connectivity and reliable distributed architecture, it ensures seamless data acquisition across harsh environments. Buy original Moxa devices from Moxa Bangladesh at the best price in BD.
Specification Table
| Specification | Value |
|---|---|
| Model | ioLogik R1240 / R1240-T |
| I/O Configuration | 8 analog input (AI) channels |
| Input Range | 0 to 10 V DC, 0 to 20 mA, 4 to 20 mA (with burn-out detection) |
| Input Mode | Differential voltage/current |
| Accuracy | ±0.1% FSR @ 25 °C; ±0.3% FSR @ –10 to 60 °C; ±0.5% FSR @ –40 to 75 °C |
| Resolution | 16 bits |
| Sampling Rate | All channels: 12 samples/sec; per channel (if only one enabled): 12 samples/sec |
| Input Impedance | Minimum 10 MΩ |
| Built-in Resistor for Current Input | 120 Ω |
| Serial Interface | 2 × RS-485 (2-wire) ports |
| Baud Rate | 1,200 to 921,600 bps |
| Isolation (I/O) | 3 k V DC or 2 k Vrms |
| Power Input Voltage | 12 to 48 V DC |
| Power Consumption | Approx. 216 mA @ 24 V DC |
| Dimensions | 27.8 × 124 × 84 mm |
| Weight | Around 200 g |
| Mounting | DIN-rail or wall mounting |
| Operating Temperature | R1240: –10 to 75 °C; R1240-T: –40 to 85 °C |
| Storage Temperature | –40 to 85 °C |
| Humidity | 5 to 95% non-condensing |
| Certifications | UL 508, EN 55032/24, CISPR 32, FCC Part 15B Class A, ESD 15 kV |
Description:
The Moxa ioLogik R1240 and R1240-T are compact RS-485 remote I/O modules designed for industrial automation applications. They feature eight high-precision analog input channels that support both voltage (0–10 V) and current (0–20 mA or 4–20 mA) signals, with differential input and 16-bit resolution for accurate signal acquisition. The device ensures reliable data performance with an accuracy of up to ±0.1% FSR at 25 °C. Two RS-485 ports allow flexible daisy-chain connections and support Modbus RTU protocol for seamless integration with PLCs, SCADA systems, and other industrial controllers.
Built to endure harsh industrial environments, the module provides 3 kV isolation protection, operates with a wide power supply range of 12–48 V DC, and consumes low power (around 216 mA at 24 V). The rugged housing supports DIN-rail and wall mounting, making installation simple. The R1240-T variant is rated for extended temperature operation from –40 °C to 85 °C, ideal for outdoor and extreme conditions. Compact, efficient, and durable, the ioLogik R1240 series is a dependable solution for analog signal monitoring, process control, and data acquisition in modern industrial systems.
Key Features
- Versatile I/O Options: Supports both analog and digital input/output, ideal for diverse industrial automation tasks.
- Remote Monitoring: Equipped with Ethernet connectivity for real-time data acquisition and remote management.
- Web-Based Configuration: Simple setup and control through a web console interface, reducing installation time.
- Modbus/TCP Protocol Support: Ensures seamless integration with SCADA and PLC systems.
- Wide Operating Temperature: The R1240-T version supports -40 to 75°C, making it reliable for harsh environments.
- Compact and Rugged Design: Built for DIN-rail mounting in industrial panels with vibration and surge protection.
- Peer-to-Peer Communication: Allows direct data exchange between multiple ioLogik modules without a controller.
Where It Can Be Used
The Moxa ioLogik R1240 series is ideal for industrial automation, energy management, factory monitoring, and building automation. It’s also widely used in water treatment plants, oil and gas systems, and transportation control. With its robust design and communication flexibility, it’s perfect for any application requiring remote data logging and control over Ethernet networks.
Installation Step
- Mount the Module: Securely attach the ioLogik R1240 to a DIN rail in your control panel.
- Connect Power Supply: Provide the rated DC power input (typically 12–48 VDC).
- Wire the I/O Channels: Connect sensors, switches, or actuators to the analog and digital terminals.
- Network Configuration: Connect an Ethernet cable to the LAN port and assign an IP address.
- Access Web Console: Open a browser and log into the web interface for initial configuration.
- Integrate with SCADA/PLC: Use Modbus/TCP or peer-to-peer functions to link with your control system.
User Experience
Users appreciate the ioLogik R1240’s reliability, easy setup, and web-based configuration tools. The device provides stable performance even in extreme industrial environments. Technicians find it simple to integrate with existing Modbus systems, reducing commissioning time. Its compact design, cost-effectiveness, and multi-protocol support make it a preferred choice for engineers seeking efficient and scalable I/O solutions for industrial automation projects.
What is the price of Moxa Iologik R1240 R1240-T Universal I/O Module in Bangladesh?
The estimated price of Moxa Iologik R1240 R1240-T Universal I/O Module in Bangladesh is 0৳. You can buy the Moxa Iologik R1240 R1240-T Universal I/O Module at best price from our website or visit our Office.
For the most accurate pricing, stock availability, and warranty details, we recommend contacting us before placing your order.

Reviews
Clear filtersThere are no reviews yet.